Meet Inspiring Speakers and Experts at our 3000+ Global Conference Series Events with over 1000+ Conferences, 1000+ Symposiums
and 1000+ Workshops on Medical, Pharma, Engineering, Science, Technology and Business.

Explore and learn more about Conference Series : World's leading Event Organizer

Back

Chao-Hui Feng

Chao-Hui Feng

University of Tokyo, Japan

Title: An alternative and innovative technique for rapid and accurate prediction of lightness of Japanese cooked pork sausages

Biography

Biography: Chao-Hui Feng

Abstract

Statement of the Problem: Lightness can greatly influence the freshness of the sausages. A precise, rapid, and non-contact analytical methods or tools is highly demanded to quantify the colour. Hyperspectral imaging (HSI) is an emerging technique which integrates spectroscopy and imaging to obtain the spectral and spatial information simultaneously. However, lightness prediction in cooked sausages using HSI has not yet been exploited. The objective was to develop a quantitative model between the spectral data and lightness values of cooked big Japanese sausages stored with different days based on partial least squares regression (PLSR). Methodology & Theoretical Orientation: Big cooked Japanese pork sausage slice (117 samples; diameter: 8.86 ± 0.37 cm; thickness: 0.12 ± 0.02 cm; mass: 6.85 ± 0.12 g) were purchased and randomly divided into 7 groups for up to 57 d storage. Image acquisition was conducted by the HSI system with the wavelength range of 380-1000 nm. The specific processing was illustrated in Figure 1. Pre-treatment methods of spectra, such as normalization (N), multiplicative scatter correction (MSC), standard normal variate (SNV), first derivative (1st D), and second derivative (2nd D) of the spectra, were conducted prior to calibration modelling. The model precision and predictive capabilities were evaluated by the coefficients of determination (Rc2 for calibration and Rp2 for prediction) and root mean square error (RMSEC for calibration and RMSEP for prediction) Findings: 10 wavelengths (390, 400, 420, 560, 685, 830, 930, 965, 980, 995) were selected as important wavelengths. Models derived from raw spectra (Rc2 = 0.68; RMSEC = 0.85; RP2 = 0.42; RMSEP = 1.19) showed similarly performance compared to those with other pre-treated spectra. A gentle better calibration result was obtained in N-PLSR model, with Rc2 of 0.69 with RMSEC of 0.83. Conclusion & Significance: The pre-treatment of SNV-PLSR and MSC-PLSR showed slight enhancement in the prediction dataset.